EPRA Class A1 Industrial Electrical Contracting & Three-Phase Power Systems

EPRA Class A1 industrial electrical contracting for factories, warehouses and plants across Kenya. Three-phase power, motor control, DB panels, ATS programming, and BOQ-backed installations.

Complete Turnkey Industrial Electrical Installations

Whether you are setting up a new manufacturing plant in Ruiru, modernizing a processing line in Thika, or expanding a warehouse in Mombasa, we handle the entire project lifecycle — from engineering design through commissioning.

Engineering Design & Detailed BOQ Development

Our registered Professional Engineers compile highly accurate Bills of Quantities (BOQ), material schedules, and detailed schematic designs. Every BOQ aligns with structural layouts and energy profiles to ensure zero cost overruns during execution.

  • Main Switchboards & Distribution Boards: Custom-built panels, motor control centers (MCCs), and sub-breakers configured to your specific industrial load requirements.
  • Cable Management Systems: Heavy-duty ladder racking, trunking, and underground ducting built to handle extreme thermal and mechanical stresses.
  • Factory & Warehouse High-Bay Lighting: Energy-efficient, high-lumen LED infrastructure engineered for industrial environments.

Power Quality Analysis & Phase Balancing

Unstable power destroys sensitive electronics, overheats heavy-duty motors, and drives up utility bills through reactive power penalties. Telligen Energy deploys specialized diagnostics to optimize your facility's power health.

High-Precision Phase Balancing

Unbalanced loads across your three-phase supply create neutral currents, trigger nuisance breaker trips, and cause voltage drops. We perform rigorous phase balancing across your facility, redistributing single-phase loads evenly to stabilize the transformer output and protect equipment from premature aging.

Advanced Power Quality Diagnostics

  • Harmonic Distortion (THD) Filtering: Mitigating electrical noise generated by non-linear loads such as variable speed drives (VSDs) and inverters.
  • Power Factor Correction (PFC): Designing and installing automated capacitor banks to bring your power factor closer to unity, eliminating Kenya Power reactive power penalties.
  • Voltage Sag & Swell Analysis: Capturing and buffering momentary voltage drops that reset automated production lines.

Statutory Regulatory Compliance & Testing

Under the Energy Act and EPRA frameworks, all large-scale commercial and industrial installations must undergo routine testing and safety audits by authorized Class A1 contractors. Telligen Energy manages the entire testing and certification framework.

  • Pre-Commissioning Testing: Insulation resistance tests, loop impedance testing, and earth continuity verification before any factory floor goes live.
  • EPRA & NCA Documentation: Certified electrical installation certificates, signed off with registered Professional Engineering stamps.
  • Energy Management Regulations Compliance: Mandatory energy audits and Energy Management Systems (EMS) for designated high-consuming facilities.

Heavy Machinery Power Integration

Integrating high-capacity machinery requires deep understanding of transient starting currents and protective coordination.

  • Motor Control & Automation: Soft-starters, Variable Frequency Drives (VFDs), and star-delta starter integrations that prevent massive voltage dips during heavy-load startup.
  • Backup Power & Hybrid Integration: Seamless interlocking of your industrial grid with automatic mains failure (AMF) panels, heavy-duty backup generators, and Solar-Diesel-BESS (Battery Energy Storage Systems) networks.

Can you work around our production schedule to minimize downtime?

Yes, scheduling around production is standard practice for us. We can plan installations and upgrades for off-hours, weekends, or planned shutdown windows.

Do you handle motor control, three-phase balancing, and ATS panel programming?

Yes. Three-phase load balancing, motor control circuit installation, automatic transfer switch (ATS) programming, and power factor correction are all core elements of our industrial electrical work.

Do you provide as-built drawings and a Bill of Quantities?

Yes. Every industrial project includes a Bill of Quantities (BOQ) before work begins and full as-built drawings on completion, as required by EPRA for licensed electrical contractors.

All ServicesCall +254 727 066 562

Explore Telligen Energy

Services: Electrical InstallationsSolar & Renewable EnergyAutomation & Smart SystemsSolar Operations & MaintenanceFire Alarms & CCTVElectrical AuditsAll servicesSolutions Catalogue

Locations: NairobiNakuruKisumuMombasaNyeriThikaEldoretKisii

Latest articles: Why Online Monitoring of Solar Power Systems Is EssentialWhy Factories Need Real-Time VisibilitySolar Power for Businesses in KenyaHow Much Does a Solar System Cost in Kenya in 2026?EPRA Licence Classes in Kenya (2026) — And How to Verify a ContractorBeyond the Paint: Why Your Dream Home Needs an Electrical Engineer

Shop: ElectricalHardwareInvertersSolarStorageAll products